1. <em id="huxqk"><object id="huxqk"><u id="huxqk"></u></object></em><tbody id="huxqk"><pre id="huxqk"></pre></tbody><button id="huxqk"><object id="huxqk"><input id="huxqk"></input></object></button>
      <em id="huxqk"><acronym id="huxqk"></acronym></em>
      <tbody id="huxqk"></tbody>

      <em id="huxqk"><strike id="huxqk"></strike></em>
    1. <th id="huxqk"><track id="huxqk"><video id="huxqk"></video></track></th>

      Home | About Biaoqi | News | Product | Contact | 中文

      Contact an Biaoqi Applications Scientist

       
      Product List
      QSpec
      OceanOpticsSpectrometer
      Light Sources
      New Product
      * PL-3000 Photoluminescence Spectrometer
      * GLIS-3000 GEM Luminous Imaging 
      * bluLoop Multi-LED Light Source
      * HL-2000 Tungsten Halogen Light 
      * LS-1 Tungsten Halogen Light So
      * DH-2000 Deuterium Tungsten Halogen&
      * Balanced Deuterium Tungsten Halogen
      * Miniature Deuterium Tungsten Haloge
      * D-2000 Deuterium Light Sources
      * High-powered Continuous-wave Xenon 
       
      Product

      OceanOpticsSpectrometer>> Fiber Optic Spectrometer>>QE65000 Scientific-grade Spectrometer  

      QE65000 Scientific-grade Spectrometer

      The QE65000 Scientific-grade Spectrometer is a novel combination of detector, optical bench and electronics technologies that provides users with a remarkably sensitive system for demanding low-light level applications such as fluorescence, DNA sequencing, astronomy and Raman spectroscopy.  The QE65000 can achieve up to 90% quantum efficiency with high signal-to-noise and rapid signal processing speed.

      • Quantum Efficiency to 90%
      • Increased System Sensitivity
      • Excellent UV Response
      • Demanding Low Light-level Applications
      • Onboard Programming
      • Multiple Interface Options
      • Optical Bench Options
      • Filter Options
      • Installation and Operation Manual
      • Specifications
      • Warranty

      New! Optical Bench Enhancements

      The great performance of our QE65000 Spectrometer has been enhanced to provide even more value: lower stray light, improved efficiency in the UV and Shortwave NIR, and better unit-to-unit reproducibility. For full UV-Shortwave NIR coverage, you'll want to configure your QE65000 with our HC-1 composite grating.

      We are also offering a proprietary low BRDF bench coating to improve stray light performance and provide better reproducibility in unit-to-unit performance.

      Quantum Efficiency to 90%

      The QE65000 is the most sensitive spectrometer we have ever developed. The Hamamatsu FFT-CCD detector used in the QE65000 provides 90% quantum efficiency (defined as how efficiently a photon is converted to a photo-electron). Most of our other detectors are linear CCDs but with this “2D” area detector, we can bin (or sum) a vertical row of pixels, which offers significant improvement in the signal-to-noise ratio (>1000:1) and signal processing speed of the detector compared with a linear CCD, where signals are digitally added by an external circuit.

      Increased System Sensitivity

      In our spectrometers with linear CCDs, the slit’s width, not its height, regulates the amount of light entering the bench because linear CCDs cannot efficiently collect the light from the entire height of the slit. But in the QE65000, the 2D area detector can better take advantage of the height of the slit and the additional light, greatly improving system sensitivity.

      Excellent UV Response

      Because the detector in the QE65000 is back-thinned (or back-illuminated), it has great native response in the UV and does not require the additional coatings that we typically apply to other detectors for UV applications.

      Demanding Low Light-level Applications

      The QE65000 Spectrometer is a great option for low-light level applications including fluorescence, Raman spectroscopy, DNA sequencing, astronomy and thin-film reflectivity. The TE-cooled (down to -15 °C) detector features low noise and low dark signal, which enables low-light-level detection and long integration times (analogous to the shutter speed of a camera) from 8 milliseconds to 15 minutes, with virtually no spectral distortion.

       

      An example of a fluorescence setup with a QE65000 uses the PX-2 Pulsed Xenon Lamp as an excitation source and the CUV-ALL Cuvette Holder for samples. An optical fiber delivers excitation light to the sample holder and read light to the spectrometer. A filter, such as one of our Linear Variable Filters would block excitation light from entering the spectrometer

      Onboard Programming

      The QE65000 also has an onboard programmable micro-controller for controlling the spectrometer and accessories. You have access to 10 user-programmable digital inputs/outputs and a pulse generator for triggering other devices. You can use the I/Os to flash a lamp, stop/start a process, and send a message/alarm during the spectrometer’s integration period. The spectrometer’s operating parameters can be controlled through software. In fact, wavelength calibration coefficients unique to each spectrometer are programmed into a memory chip right on the spectrometer.

      Multiple Interface Options

      The QE65000 interfaces to a computer via USB 2.0 or RS-232 serial port. When combined with the Remora Network Adapter, the USB interface allows you communication via Ethernet and/or wireless network. Data unique to each spectrometer are programmed into a memory chip on the QE65000; our SpectraSuite Spectroscopy Operating Software reads these values for easy setup and hot swapping among computers, whether they run on Linux, Mac or Windows operating systems.

      Optical Bench Options

      At Ocean Optics, we understand that your work is unique and that you want a spectrometer to fit your specific needs. With the QE65000 Spectrometer, you can configure the bench for your application. Choose QE65000 Optical Bench Options such as entrance aperture size, detector accessories, filters a grating and more. Our application scientists will help you determine which configuration will best work for you.

      Variety of Filter Options Available

      We have a number of variable bandpass order-sorting filter options available to vary the starting wavelength at 50 nm intervals to fit your particular application. These OFLVs are for use with the HC-1 grating only and consist of the following:

      Triggering Options

      The QE65000 is available with external triggering that helps you easily synchronize data acquisition with external events. Check out the documentation (PDF format):

      • External Triggering for Firmware versions below 3.0

      • External Triggering for Firmware 3.0 and above

      OFLV Filter Wavelength Range
      OFLV-QE 200-950 nm
      OFLV-QE-250 250-1000 nm
      OFLV-QE-300 300-1050 nm
      OFLV-QE-350 350-1100 nm
      OFLV-QE-400 400-1150 nm

      Installation and Operation Manual

      Our QE65000 Manual provides you with instructions for setting up, calibrating and performing experiments with your QE65000 spectrometer.

      Specifications

      Physical

      Dimensions: 182 mm x 110 mm x 47 mm
      Weight: 1.18 kg (without power supply)
      Detector

      Detector:

      Hamamatsu S7031-1006

      Detector range: 200-1100 nm

      Pixels:

      1024 x 58 (1044 x 64 total pixels)

      Pixel size:

      24.576 μm2

      Pixel well depth:

      1000 Ke-

      Sensitivity: ~0.065 counts / e-
      Quantum efficiency: 90% peak; 65% at 250 nm
      Optical Bench
      Design: f/4, Symmetrical crossed Czerny-Turner
      Focal length: 101.6 mm input and output
      Entrance aperture: 5, 10, 25, 50, 100 or 200 µm wide slits or fiber (no slit)
      Grating options: 14 different grating options, UV through Shortwave NIR
      HC1-QE grating option: provides UV-Shortwave NIR coverage
      Detector collection lens option: None
      OFLV filter options: OFLV-QE (200-950 nm); OFLV-QE-250 (250-1000 nm); OFLV-QE-300 (300-1050 nm); OFLV-QE-350 (350-1100 nm); OFLV-QE-400 (400-1150 nm)
      Other bench filter options: Longpass OF-1 filters
      Collimating and focusing mirrors: Standard only
      UV enhanced window: No
      Fiber optic connector: SMA 905 to 0.22 numerical aperture single-strand optical fiber
      Spectroscopic
      Wavelength range: Grating dependent
      Optical resolution: ~0.14-7.7 nm FWHM
      Signal-to-noise ratio: 1000:1 (at full signal)
      A/D resolution: 16 bit
      Dark noise: 3 RMS counts
      Dynamic range: 7.5 x 109 (system), 25000:1 for a single acquisition
      Integration time: 8 ms to 15 minutes
      Stray light: <0.08% at 600 nm; 0.4% at 435 nm
      Corrected linearity: >99.8%
      Electronics
      Power consumption: 500 mA @ 5 VDC (no TE cooling); 3.5 A @ 5 VDC (with TE cooling)
      Data transfer speed: Full scans to memory every 7 ms with USB 2.0 port, 18 ms with USB1.1 port, 300 ms with serial port
      Inputs/Outputs: 10 onboard digital user-programmable GPIOs (general purpose inputs/outputs)
      Analog channels: No
      Auto nulling: Yes
      Breakout box compatibility: Yes, HR4-BREAKOUT
      Trigger modes: 4 modes
      Strobe functions: No
      Gated delay feature: Yes
      Connector: 30-pin connector
      Power-up time: <5 seconds

      Dark current:

      4000 e-/pixel/sec @ 25 ºC; 200 e-/pixel/sec @ 0 ºC

      Computer
      Operating systems: Windows 98/Me/2000/XP, Mac OS X and Linux with USB port; Any 32-bit Windows OS with serial port
      Computer interfaces: USB 2.0 @ 480 Mbps; RS-232 (2-wire) @ 115.2 K baud
      Network Access: Remora's USB interface adapts for Ethernet Connectivity
      Peripheral interfaces: SPI (3-wire); I2C inter-integrated circuit
      Temperature and Thermoelectric (TE) Cooling
      Temperature limits: 0 ºC to 50.0 ºC; no condensation
      Set point: Software controlled; lowest set point is 40 ºC below ambient
      Stability +/-0.1 ºC of set temperature in <2 minutes

      Systems starting at. Ask an Ocean Optics Applications Scientist about configuration options, software requirements and optional accessories.

       