1. <em id="huxqk"><object id="huxqk"><u id="huxqk"></u></object></em><tbody id="huxqk"><pre id="huxqk"></pre></tbody><button id="huxqk"><object id="huxqk"><input id="huxqk"></input></object></button>
      <em id="huxqk"><acronym id="huxqk"></acronym></em>
      <tbody id="huxqk"></tbody>

      <em id="huxqk"><strike id="huxqk"></strike></em>
    1. <th id="huxqk"><track id="huxqk"><video id="huxqk"></video></track></th>

      Home | About Biaoqi | News | Product | Contact | 中文

      Contact an Biaoqi Applications Scientist

       
      Product List
      QSpec
      OceanOpticsSpectrometer
      Light Sources
      New Product
      * PL-3000 Photoluminescence Spectrometer
      * GLIS-3000 GEM Luminous Imaging 
      * bluLoop Multi-LED Light Source
      * HL-2000 Tungsten Halogen Light 
      * LS-1 Tungsten Halogen Light So
      * DH-2000 Deuterium Tungsten Halogen&
      * Balanced Deuterium Tungsten Halogen
      * Miniature Deuterium Tungsten Haloge
      * D-2000 Deuterium Light Sources
      * High-powered Continuous-wave Xenon 
       
      Product

      OceanOpticsSpectrometer>> Oxygen Sensors System>>FOSPOR Sensor Formulation  

      FOSPOR Sensor Formulation


      The FOSPOR coating is applied to the distal end of the fiber and has a fluorescence-based Pt-porphyrin indicator. The sensor uses fluorescence quenching of the porphyrin to measure the partial pressure of dissolved or gaseous oxygen. The FOSPOR coating can be applied to substrates other than fibers and probes and used for applications such as through-packaging measurements in the food and pharmaceutical industries. *Please contact an Applications Scientist before specifying FOSPOR or other coatings.

      Choosing a Probe
      Once you choose the best Sensor Coating Formulation for your application, you need to select the fiber optic probe onto which the sensor coating is applied. For a list of fiber optic probes, click here.

      FOSPOR Coating Specifications

      Specification  
      Principle Photoluminescence-quenching using Pt compound. Measures O2 partial pressure.
      Sensor mechanism Phase shift due to change in partial pressure of O2
      Applications Low O2 (0–5%), vacuum systems packaging, benign environment
      Time-constant (µsec) dynamic range Air: 10.00; N2: 50.00; Low: 3.00, High: 70.00
      Accuracy: (0–20% O2, 0–50ºC) <5% of reading (using polynomial fit to multipoint calibration)
      Response time of probe with no overcoat <30-60 seconds in gas, 60-90 seconds in liquid
      Response time of dissolved oxygen in liquid (with overcoat) 30-45 seconds
      Response time of probe with Overcoat of Oxygen Gas (at 1 atmosphere) 60-120 seconds
      Dynamic range of Dissolved Oxygen in liquid 0–4.1 ppm; 0–75 mm Hg partial pressure
      Dynamic range of Oxygen Gas (at 1 atmosphere) 0–<10% (mole percent); 0–760 mm Hg partial pressure
      Stability Dissolved Oxygen in liquid Drift < 0.00008 ppm O2 per hour at low dissolved oxygen; Drift ~ 0.006 ppm O2 per hour in air-saturated water
      Stability Oxygen Gas (at 1 atmosphere) Drift ~ 0.0002% O2 drift per hour at low O2; Drift ~ 0.015% O2 per hour air
      Resolution of Dissolved Oxygen in liquid 0.002 ppm at room temperature
      Resolution of Oxygen Gas (at 1 atmosphere) 0.005% at room temperature
      Lowest detectable limit of Dissolved Oxygen in liquid 0.002 ppm at room temperature
      Lowest detectable limit of oxygen gas (at 1 atmosphere) 0.005% (0.04 mm Hg)
      Overcoat available Yes
      Temperature range 0ºC to +60ºC
      Temperature Temperature sensor and software-supported compensation
      Temperature recalibration Only when probe is replaced/refurbished
      Probe lifetime Reconditioning recommended once per year
      pH operating range 1-10 pH
       