1. <em id="huxqk"><object id="huxqk"><u id="huxqk"></u></object></em><tbody id="huxqk"><pre id="huxqk"></pre></tbody><button id="huxqk"><object id="huxqk"><input id="huxqk"></input></object></button>
      <em id="huxqk"><acronym id="huxqk"></acronym></em>
      <tbody id="huxqk"></tbody>

      <em id="huxqk"><strike id="huxqk"></strike></em>
    1. <th id="huxqk"><track id="huxqk"><video id="huxqk"></video></track></th>

      Home | About Biaoqi | News | Product | Contact | 中文

      Contact an Biaoqi Applications Scientist

       
      Product List
      QSpec
      OceanOpticsSpectrometer
      Light Sources
      New Product
      * PL-3000 Photoluminescence Spectrometer
      * GLIS-3000 GEM Luminous Imaging 
      * bluLoop Multi-LED Light Source
      * HL-2000 Tungsten Halogen Light 
      * LS-1 Tungsten Halogen Light So
      * DH-2000 Deuterium Tungsten Halogen&
      * Balanced Deuterium Tungsten Halogen
      * Miniature Deuterium Tungsten Haloge
      * D-2000 Deuterium Light Sources
      * High-powered Continuous-wave Xenon 
       
      Product

      OceanOpticsSpectrometer>> Oxygen Sensors System>>HIOXY Sensor Formulation  

      HIOXY Sensor Formulation


      Two years of research and development pursuing a high-performance oxygen sensor compatible with hydrocarbon environments has resulted in our new HIOXY sensor. The HIOXY sensor is designed for monitoring oxygen partial pressure in non-aqueous vapors and solutions. The sensor coating chemistry is ideal for use with oils, alcohols and hydrocarbon-based vapors and liquids. HIOXY has been tested successfully in commercial and military aviation fuels, gasoline, diesel, some alcohols, glycol, military hydraulic fluids and wine analysis.

      Choosing a Probe
      Once you choose the best Sensor Coating Formulation for your application, you need to select the fiber optic probe onto which the sensor coating is applied. For a list of fiber optic probes, click here.

      HIOXY Coating Specifications

      Specification  
      Principle Photoluminescence-quenching using Ru compound. Measures O2 partial pressure.
      Sensor mechanism Phase shift due to change in partial pressure of O2
      Applications Hydrocarbon-based liquids and vapors, fuels, alcoholic beverages, vegetable oil
      Time-constant (µsec) dynamic range Air: 0.50, N2: 2.50; Low: 0.30, High: 6.00
      Accuracy: (0–20% O2, 0–50ºC) <5% of reading (using polynomial fit to multipoint calibration)
      Response time of probe with no overcoat <1 second in gas, 30-45 seconds in liquid
      Response time of dissolved oxygen in liquid (with overcoat) Overcoat not required
      Response time of probe with Overcoat of Oxygen Gas (at 1 atmosphere) Overcoat not required
      Dynamic range of Dissolved Oxygen in liquid 0–8.7 ppm; 0–170 mm Hg partial pressure
      Dynamic range of Oxygen Gas (at 1 atmosphere) 0–20.9% (mole percent); 0–160 mm Hg partial pressure
      Stability Dissolved Oxygen in liquid Drift<0.002 ppm per hour
      Stability Oxygen Gas (at 1 atmosphere)

      Drift ~0.01% O2 per hour

      Resolution of Dissolved Oxygen in liquid 0.02 ppm at room temperature
      Resolution of Oxygen Gas (at 1 atmosphere) 0.05% (0.4 mmHg) at room temperature
      Lowest detectable limit of Dissolved Oxygen in liquid 0.02 ppm
      Lowest detectable limit of oxygen gas (at 1 atmosphere) 0.05% (0.4 mm Hg)
      Overcoat available No overcoat available
      Temperature range -50ºC to +60ºC
      Temperature Temperature sensor and software-supported compensation
      Temperature recalibration Only when probe is replaced/refurbished
      Probe lifetime Reconditioning recommended once per year
      pH operating range 1-10 pH
       