1. <em id="huxqk"><object id="huxqk"><u id="huxqk"></u></object></em><tbody id="huxqk"><pre id="huxqk"></pre></tbody><button id="huxqk"><object id="huxqk"><input id="huxqk"></input></object></button>
      <em id="huxqk"><acronym id="huxqk"></acronym></em>
      <tbody id="huxqk"></tbody>

      <em id="huxqk"><strike id="huxqk"></strike></em>
    1. <th id="huxqk"><track id="huxqk"><video id="huxqk"></video></track></th>

      Home | About Biaoqi | News | Product | Contact | 中文

      Contact an Biaoqi Applications Scientist

       
      Product List
      QSpec
      OceanOpticsSpectrometer
      Light Sources
      New Product
      * PL-3000 Photoluminescence Spectrometer
      * GLIS-3000 GEM Luminous Imaging 
      * bluLoop Multi-LED Light Source
      * HL-2000 Tungsten Halogen Light 
      * LS-1 Tungsten Halogen Light So
      * DH-2000 Deuterium Tungsten Halogen&
      * Balanced Deuterium Tungsten Halogen
      * Miniature Deuterium Tungsten Haloge
      * D-2000 Deuterium Light Sources
      * High-powered Continuous-wave Xenon 
       
      Product

      OceanOpticsSpectrometer>> Fiber Optic Spectrometer>>HR4000 High-Resolution Spectrometer-Ocean Optics  
      HR4000 High-Resolution Spectrometer

      Our next-generation high-resolution spectrometer is a novel combination of optics and electronics that is ideal for applications such as characterizing lasers, measuring gas absorbance, and determining atomic emission lines. The HR4000 is available for beginning at.

      • 0.02 nm Optical Resolution (FWHM) Possible
      • Electronic Shutter Prevents Saturation
      • Onboard Microcontroller
      • Network Access via Ethernet
      • Multiple Interface Options
      • Optical Bench Options
      • Installation and Operation Manual
      • Accessories
      • Pricing
      • Specifications

      0.02 nm Optical Resolution (FWHM) Possible

      The HR4000 Spectrometer is our next-generation high-resolution spectrometer. The HR4000 has a 3648-element CCD-array detector from Toshiba that enables optical resolution as precise as 0.02 nm (FWHM). The HR4000 is responsive from 200-1100 nm, but the specific range and resolution depend on your grating and entrance slit choices. This novel combination of optics and electronics is ideal for applications such as characterizing lasers, measuring gas absorbance, and determining atomic emission lines.

      Electronic Shutter Prevents Saturation

      Integration Time is a setting in our software that is specified by the user. It’s analogous to the shutter speed of a camera: the value specified for the integration time is the amount of time the detector “looks” at the incoming photons. Because the Toshiba detector has an electronic shutter, you can specify, via software, minimum integration times as short as 3.8 milliseconds, which allow you to measure transient events like laser pulses (for even faster integration times using the External Hardware Trigger Mode, see our HR2000+ Spectrometer). Also, the ability to integrate the spectrometer for short durations eliminates saturation problems that can occur in high light-level applications such as laser analysis.

      Onboard Microcontroller

      The HR4000’s onboard microcontroller provides you with considerable flexibility in controlling the spectrometer and accessories. Through a 30-pin connector, you can implement all operating parameters in the software: control light sources, create processes, and retrieve information on external objects. You have access to 10 user-programmable digital inputs/outputs for interfacing to other equipment; one analog input and one analog output; and a pulse generator for triggering other devices. (Programming the GPIOs requires SpectraSuite, OmniDriver or one of our other device drivers.)

      Turn HR4000 into a Network Spectrometer

      When purchased with the Remora Network Adapter users can communicate with the HR4000 over Ethernet or Wi-Fi. Use with SpectraSuite Software, and turn your device into a network accessible spectrometer. Remotely capture spectral data from anywhere Plus, Remora allows multiple users to access data and experiment settings without the need for additional equipment. Remora's web-interface works with all popular web browsers and allows you to monitor data from a PDA, iPhone, and most internet ready devices.

      Multiple Interface Options

      The HR4000 interfaces to a computer via USB 2.0 or RS-232 serial port. When combined with the Remora Network Adapter, the USB interface allows you communication via Ethernet and/or wireless network. When using the serial port, the HR4000 requires a single 5-volt power supply (not included). Data unique to each spectrometer are programmed into a memory chip on the HR4000; our SpectraSuite Spectroscopy Operating Software reads these values for easy setup and hot swapping among computers, whether they run on Linux, Mac or Windows operating systems.

      Optical Bench Options

      At Ocean Optics, we understand that your work is unique and that you want a spectrometer to fit your specific needs. With the HR4000 Spectrometer, you can configure the bench for your application. Choose HR4000 Optical Bench Options such as entrance aperture size, detector accessories, filters a grating and more. Our application scientists will help you determine which configuration will best work for you.

      Installation and Operation Manual

      Our HR4000 Manual provides you with instructions for setting up, calibrating and performing experiments with your HR4000 spectrometer.

      Breakout Box Accessory

      The HR4-BREAKOUT is a passive module that provides access to a variety of functions found in the HR4000. The BREAKOUT BOX allows multiple interfaces to a spectrometer such as: external triggering, GPIO, light sources, RS-232 interface and analog input/output.

      Pricing

      Item Description
      HR4000 HR4000 User-configured Spectrometer. User to specify an HR4000 Detector (see 3 detector options) and HR400 Spectrometer Optical Bench Options
      HR4-BREAKOUT Breakout Box with easy access to HR4000 Functions
      SpectraSuite SpectraSuite Spectroscopy Operating Software

      Specifications

      Physical

      Dimensions: 148.6 mm x 104.8 mm x 45.1 mm
      Weight: 570 grams
      Detector

      Detector:

      Toshiba TCD1304AP linear CCD array

      Detector range: 200-1100 nm

      Pixels:

      3636 pixels

      Pixel size:

      8 μm x 200 μm

      Pixel well depth:

      ~100,000 electrons

      Sensitivity: 130 photons/count at 400 nm; 60 photons/count at 600 nm
      Optical Bench
      Design: f/4, Symmetrical crossed Czerny-Turner
      Focal length: 101.6 mm input and output
      Entrance aperture: 5, 10, 25, 50, 100 or 200 µm wide slits or fiber (no slit)
      Grating options: 14 different gratings, UV through Shortwave NIR
      HC-1 grating option: provides 200-1050 nm range (best efficiency)
      Detector collection lens option: Yes, L4
      OFLV filter options: OFLV-200-1100
      Other bench filter options: Longpass OF-1 filters
      Collimating and focusing mirrors: Standard or SAG+UPG-HR
      UV enhanced window: Yes, UV4
      Fiber optic connector: SMA 905 to 0.22 numerical aperture single-strand optical fiber
      Spectroscopic
      Wavelength range: Grating dependent
      Optical resolution: ~0.02-8.4 nm FWHM
      Signal-to-noise ratio: 300:1 (at full signal)
      A/D resolution: 14 bit
      Dark noise: 12 RMS counts
      Dynamic range: 2 x 10^8 (system); 1300:1 for a single acquisition
      Integration time: 3.8 ms to 10 seconds
      Stray light: <0.05% at 600 nm; <0.10% at 435 nm
      Corrected linearity: >99.8%
      Electronics
      Power consumption: 450 mA @ 5 VDC
      Data transfer speed: Full scans to memory every 4 ms with USB 2.0 port
      Inputs/Outputs: Yes, 10 onboard digital user-programmable GPIOs
      Analog channels: One 13-bit analog input; one 9-bit analog output
      Auto nulling: No
      Breakout box compatibility: Yes, HR4-BREAKOUT
      Trigger modes: 4 modes
      Strobe functions: Yes
      Gated delay feature: No
      Connector: 30-pin connector
      Computer
      Operating systems: Windows 98/Me/2000/XP, Mac OS X and Linux with USB port; Any 32-bit Windows OS with serial port
      Network Access: Remora's USB interface adapts for Ethernet Connectivity
      Computer interfaces: USB 2.0 @ 480 Mbps; RS-232 (2-wire) @ 115.2 K baud
      Peripheral interfaces: SPI (3-wire); I2C inter-integrated circuit
       