1. <em id="huxqk"><object id="huxqk"><u id="huxqk"></u></object></em><tbody id="huxqk"><pre id="huxqk"></pre></tbody><button id="huxqk"><object id="huxqk"><input id="huxqk"></input></object></button>
      <em id="huxqk"><acronym id="huxqk"></acronym></em>
      <tbody id="huxqk"></tbody>

      <em id="huxqk"><strike id="huxqk"></strike></em>
    1. <th id="huxqk"><track id="huxqk"><video id="huxqk"></video></track></th>

      Home | About Biaoqi | News | Product | Contact | 中文

      Contact an Biaoqi Applications Scientist

       
      Product List
      QSpec
      OceanOpticsSpectrometer
      Light Sources
      New Product
      * PL-3000 Photoluminescence Spectrometer
      * GLIS-3000 GEM Luminous Imaging 
      * bluLoop Multi-LED Light Source
      * HL-2000 Tungsten Halogen Light 
      * LS-1 Tungsten Halogen Light So
      * DH-2000 Deuterium Tungsten Halogen&
      * Balanced Deuterium Tungsten Halogen
      * Miniature Deuterium Tungsten Haloge
      * D-2000 Deuterium Light Sources
      * High-powered Continuous-wave Xenon 
       
      Product

      OceanOpticsSpectrometer>> Fiber Optic Spectrometer>>USB4000 Miniature Fiber Optic Spectrometer-Ocean Optics  

      USB4000 Miniature Fiber Optic Spectrometer


      We’ve sold over 130,000 spectrometer channels for thousands of applications, and we've used that experience to make the most flexible, versatile and cost-effective spectrometer ever built. The USB4000 is our next-generation flagship spectrometer, with a 3648-element Toshiba linear CCD array for increased signal-to-noise and enhanced electronics for controlling the spectrometer and accessories. The USB4000 starts at. The USB4000 is made-to-order per your optical bench selections -- including order-sorting filters and entrance slits sizes -- which are available as separate line items.

      Pre-configured USB4000-UV-VIS & USB4000-VIS-NIR are in-stock and ready to ship!

      • World's Most Popular Spectrometer Just Got Better
      • Electronic Advancements
      • Streamlined Start-up Software & Hot Swapping
      • Optical Bench Options
      • Detector Options
      • Installation and Operation Manual
      • Sampling Accessories
      • Pricing
      • Specifications

      World’s Most Popular Spectrometer Just Got Better

      We redesigned the USB2000 -- the most popular spectrometer in the world -- to include an advanced detector and powerful high-speed electronics. The USB4000 features a 16-bit A/D, four triggering options, a dark-level correction during temperature changes, and a 22-pin connector with eight user-programmable GPIOs. What’s more, the USB4000 interfaces to computers with Linux, Mac or Windows operating systems. The modular USB4000 is responsive from 200-1100 nm and can be configured with various Ocean Optics optical bench accessories, light sources and sampling optics to create application-specific systems for thousands of absorbance, reflection and emission applications.

      Electronic Advancements

      The USB4000 Spectrometer is distinguished by its enhanced electronics: 16-bit A/D resolution with auto nulling feature (an enhanced electrical dark-signal correction); EEPROM storage of calibration coefficients for simple spectrometer start-up; 8 programmable GPIO signals for controlling peripheral devices; and an electronic shutter for spectrometer integration times as fast as 3.8 milliseconds -- a handy feature to prevent detector saturation (for faster integration times using the External Hardware Trigger Mode, see our USB2000+ Spectrometer). In addition, the USB4000 has signal-to-noise of 300:1 and optical resolution (FWHM) ranging from 0.3-10.0 nm (depending on your grating and entrance aperture selection).

      Streamlined Start-up Software & Hot Swapping

      The USB4000 interfaces to a computer via USB 2.0 or RS-232 serial port. Data unique to each spectrometer is programmed into a memory chip on the USB4000; SpectraSuite Spectroscopy Operating Software reads these values for easy setup and hot swapping among computers, whether they run on Linux, Mac or Windows operating systems. When connected to a computer via USB, the USB4000 draws its power from the computer. With its small-footprint design, plug-and-play convenience, advanced electronics and powerful detector, the USB4000 has succeed the USB2000 as the most frequently specified fiber optic spectrometer in the world.

      Optical Bench Options

      At Ocean Optics, we understand that your work is unique and that you want a spectrometer to fit your specific needs. What makes the USB4000 Spectrometer so special are the options that allow you to configure the bench for your application. Choose USB4000 Optical Bench Option such as entrance aperture size, detector accessories, filters a grating and more. Our application scientists will help you determine which configuration will best work for you.

      We also have a limited-time upgrade offer designed especially to enhance your UV sensing and boost UV response by over 20%. The upgrade is available for Gratings 1, 5, 7 and 10.

      Detector Options

      The USB4000 uses the Toshiba TCD1304AP 3648-element linear CCD-array detector. To properly configure a USB4000 Spectrometer for your application, you'll need to specify one of the Four Detector Options offered; all four options include the Toshiba detector but with different coatings and windows. Your application scientist can help you determine which detector options will best work for you.

      Installation and Operation Manual

      Our USB4000 Manual provides you with instructions for setting up, calibrating and performing experiments with your USB4000 spectrometer.

      Sampling Accessories

      When you purchase a USB4000, you can also choose from Ocean Optics' complete line of spectroscopic accessories.  Most accessories have SMA 905 connectors for application flexibility. Changing the sampling system is as easy as unscrewing a connector and adding new components or accessories, such as USB4000 direct-attach accessories, and additional light sources, sampling holders, filter holders, flow cells, fiber optic probes and sensors, collimating lenses, attenuators, diffuse reflectance standards, integrating spheres and our extensive line of optical fibers.

      Pricing

      Item Description Price
      USB4000 USB4000 User-configured Spectrometer. User to specify a USB4000 Detector (see 4 detector options) and USB4000 Spectrometer Optical Bench Options *
      SpectraSuite SpectraSuite Spectroscopy Operating Software

      * Pre-configured, off-the-shelf USB4000 Spectrometers (such as the USB4000-UV-VIS, USB4000-VIS-NIR and USB4000-FL) have the detector and other bench components built-in.

      Specifications

      Physical

      Dimensions: 89.1 mm x 63.3 mm x 34.4 mm
      Weight: 190 grams
      Detector Specifications

      Detector:

      Toshiba TCD1304AP Linear CCD array

      Detector range: 200-1100 nm

      Pixels:

      3648 pixels

      Pixel size:

      8 μm x 200 μm

      Pixel well depth:

      100,000 electrons

      Signal-to-noise ratio: 300:1 (at full signal)
      A/D resolution: 16 bit
      Dark noise: 50 RMS counts
      Corrected linearity: >99.8%
      Sensitivity: 130 photons/count at 400 nm; 60 photons/count at 600 nm
      Optical Bench
      Design: f/4, Asymmetrical crossed Czerny-Turner
      Focal length: 42 mm input; 68 mm output
      Entrance aperture: 5, 10, 25, 50, 100 or 200 µm wide slits or fiber (no slit)
      Grating options: 14 different grating options, UV through Shortwave NIR
      HC-1 grating option: No
      Detector collection lens option: Yes, L4
      DET4 filter options: DET4-200-850; DET4-350-1000
      Other bench filter options: Longpass OF-1 filters
      Collimating and focusing mirrors: Standard or SAG+UPG
      UV enhanced window: Yes, UV4
      Fiber optic connector: SMA 905 to 0.22 numerical aperture single-strand optical fiber
      Spectroscopic
      Wavelength range: Grating dependent
      Optical resolution: ~0.3-10.0 nm FWHM (grating dependent)
      Signal-to-noise ratio: 300:1 (at full signal)
      A/D resolution: 16 bit
      Dark noise: 50 RMS counts
      Integration time: 3.8 ms - 10 seconds
      Dynamic range: 2 x 108 (system), 1300:1 for a single acquisition
      Stray light: <0.05% at 600 nm; 0.10% at 435 nm
      Electronics
      Power consumption: 250 mA @ 5 VDC
      Data transfer speed: Full spectrum to memory every 4 ms with USB 2.0 port
      Inputs/Outputs: Yes, 8 onboard digital user-programmable GPIOs
      Analog channels: No
      Auto nulling: Yes
      Breakout box compatible: Yes, with the USB-ADP-BB adapter
      Trigger modes: 4 modes
      Strobe functions: Yes
      Connector: 22-pin connector
      Computer
      Operating systems: Windows 98/Me/2000/XP, Mac OS X and Linux with USB port; Any 32-bit Windows OS with serial port
      Computer interfaces: USB 2.0 @ 480 Mbps (USB1.1 compatible); RS-232 (2-wire) @ 115.2 K baud
      Peripheral interfaces: SPI (3-wire); I2C inter-integrated circuit

      Serial port operation tips: When using the serial port, the USB4000 requires a single 5-volt power supply (not included). Also, SpectraSuite Spectroscopy Software does not support spectrometer operation via the serial port. However, using the included Serial Port Command Set, you can write your own software that makes serial port operation possible.

       