      QSpec
      OceanOpticsSpectrometer
      Light Sources
      New Product
      * PL-3000 Photoluminescence Spectrometer
      * GLIS-3000 GEM Luminous Imaging 
      * bluLoop Multi-LED Light Source
      * HL-2000 Tungsten Halogen Light 
      * LS-1 Tungsten Halogen Light So
      * DH-2000 Deuterium Tungsten Halogen&
      * Balanced Deuterium Tungsten Halogen
      * Miniature Deuterium Tungsten Haloge
      * D-2000 Deuterium Light Sources
      * High-powered Continuous-wave Xenon 
       
      Product

      OceanOpticsSpectrometer>> Raman Spectrometer>>Fiber optic probes for Raman spectroscopy  

      We offer several fiber optic probes for Raman spectroscopy. The RIP-series probes described here are from our partner InPhotonics, and provide optical filtering of the Rayleigh line and high signal collection in a compact, rugged design. Several probe models are available for laboratory, industrial and environmental applications and are available for several excitation wavelengths.

       

      These probes are compatible with Ocean Optics systems configured for Raman spectroscopy.

       

      We also have available the RAM-PR-S probe, which can be purchased individually or as part of the R-3000 Raman System.


      General Purpose Raman Probes
       

      Item Code

      Description

      Dimensions

      RIP-RPB-785-0.26

      Raman Probe for 785 nm laser, steel jacketed fibers

      107 x 38 x 12.7 mm, 0.26 m steel-jacketed fiber

      RIP-RPB-532

      Laboratory probe for use with lasers up to 3 nm from specified operating wavelength

      107 x 38 x 12.7 mm, 9.5 OD x 38 mm extension, 1.5-meter fiber

      RIP-RPB-532-FC

      Raman coupled fiber probe for 532 nm with FC connector

      107 x 380 x 9.57 mm, 1.5-meter fiber

      RIP-RPB-785-FC

      Raman coupled fiber probe for 785 nm with FC connector 7.5 mm working distance

      107 x 380 x 9.57 mm, 1.5-meter fiber

      RIP-RPB-785-SS

      Raman coupled fiber probe for 785 nm with SMA connector 7.5 mm working distance

      107 x 380 x 9.57 mm, 1.5-meter fiber

      RIP-RPS-532

      Stainless-steel focused probe 12.7 mm diameter

      12.7 OD x 108 mm, 5-meter fiber

      RIP-RPS-532-IP

      Stainless-steel focused probe for 532 nm excitation wavelength setups

      12.7 OD x 108 mm, 5-meter fiber

      RIP-RPS-785

      Stainless-steel focused probe for 785 nm excitation wavelength setups

      12.7 OD x 108 mm, 5-meter fiber

      RIP-RPB-785-0.6

      Raman coupled probe for 785 nm, steel jacketed fibers

      107 x 38 x 12.7 mm, 0.6 m steel-jacketed fiber


      Immersion Probes

      Item Code

      Description

      Dimensions

      RIP-RP2-532

      Stainless-steel immersion probe is immersible up to 200 °C and has adjustable working distance for 532 nm excitation wavelength setups

      15.87 OD x 230 mm; 5-meter fiber

      RIP-RP2-785

      Stainless-steel immersion probe is immersible up to 200 °C and has adjustable working distance for 785 nm excitation wavelength setups

      15.87 OD x 230 mm; 5-meter fiber

      RIP-RPR-H-532

      Hastelloy C immersion probe for use in process control applications up to 200 °C and 1500 psi; comes with sapphire window and has adjustable working distance for

      532 nm excitation wavelength setups

      15.87 OD x 230 mm; 5-meter fiber

      RIP-RPR-H-785

      Hastelloy C immersion probe for use in process control applications up to 200 °C and 1500 psi; comes with sapphire window and has adjustable working distance for
      785 nm excitation wavelength setups

      15.87 OD x 230 mm; 5-meter fiber

      RIP-RPR-SS-532

      Stainless-steel immersion probe for use in process control applications up to 200 °C and 1500 psi; sapphire window with adjustable working distance for 532 nm excitation wavelength setups

      15.87 OD x 230 mm; 5-meter fiber

      RIP-RPR-SS-785

      Stainless-steel immersion probe for use in process control applications up to 200 °C and 1500 psi; sapphire window with adjustable working distance for 785 nm excitation wavelength setups

      15.87 OD x 230 mm; 5-meter fiber


      Process Probes

      Item Code

      Description

      Dimensions

      RIP-RPP-532

      Stainless-steel probe with external optics for process control applications up to 500 °C and 3000 psi; comes with sapphire lens and has short working distance for 532 nm excitation wavelength setups

      9.52 OD x 300 mm; 5-meter fiber

      RIP-RPP-785

      Stainless-steel probe with external optics for process control applications up to 500 °C and 3000 psi; comes with sapphire lens and has short working distance for 785 nm excitation wavelength setups

      9.52 OD x 300 mm; 5-meter fiber


      * RIP-RPB is available for 532 nm, 633 nm and 785 nm excitation wavelengths; additional excitation wavelength options are available on request. RIP-RPB Probes have laser filtering of 106. All other probes are available for 514 nm, 532 nm, 670 nm, 785 nm and 830 nm excitation wavelengths, with laser filtering of 108.

       